8.3.3 test machine should have the following functions: test time or preset function;
Dynamic timing or counting function; test amplitude display or control function; automatic stop function.
Evaluation of 8.4 spring fatigue test results
8.4.1 fatigue life determination: under a given failure condition, the measured spring reaches
The maximum cycle number is the fatigue life of the spring.
Verification of 8.4.2 fatigue life: if the number of cycles is tested, if the spring does not fail
The validation test proved that the test was passed.
8.4.3 reliability verification: according to the given reliability target value, determine the suitability according to the regulations.
The number of samples n, under specified test conditions and requirements, according to the required failure mode.
Judge. If the qualified number is greater than the minimum qualified number r required, the verification test is required.
Pass through, and vice versa.
The relaxation rate of 8.4.4 spring: the relaxation rate of spring.
The number indicates:
Epsilon =F-fiX 100%
Spring load measured before F test
The spring load measured after the Fi-- test.
The relaxation rate after fatigue test should be within the prescribed range.